Faults we diagnose and repair
Loss of system pressure
A steady fall in pressure points to water leaving the system, through a radiator valve, a failed expansion vessel, the safety valve or concealed pipework. We locate the source so the problem is resolved rather than masked.
Intermittent hot water
On combination boilers, temperatures that fluctuate or fade are often traced to a diverter valve, a flow sensor or scale in the plate heat exchanger.
Zoned systems not responding
In larger homes with separate upstairs, downstairs and hot water zones, a single failed motorised valve, wiring centre or thermostat can leave part of the house cold. We test each zone methodically.
Lockouts and ignition faults
A boiler that refuses to light or repeatedly locks out may have a fan, gas valve, electrode or condensate issue. We test components rather than replacing parts on speculation.
Noise and poor circulation
Kettling, gurgling and radiators that heat unevenly are frequently caused by sludge, air or a weakening pump. A magnetic filter and a system clean can transform an older installation.
Manufacturers
We repair boilers from Worcester Bosch, Vaillant, Viessmann, Ideal, Baxi, Glow-worm, Potterton, Intergas and Alpha, including larger system and heat-only models found in Solihull's bigger homes.
When repair is no longer sensible
On occasion a repair is not the best use of your money, perhaps because parts are discontinued or the heat exchanger has failed on an older boiler. In that case we will say so, explain the reasoning and, if you wish, prepare a separate proposal for a replacement.
Helpful details when you telephone
- The make and model, usually on the front casing or a data plate beneath
- Any error code or warning light shown on the display
- The reading on the pressure gauge
- Whether the fault affects heating, hot water or both